LE100/1 Manyetik sensör – ±3 µm – 1 Vpp (sincos)

  • Repeat accuracy max. ±1 μm
  • LED status display
  • Works with MB100/1 magnetic tape
  • Works with MBR100 magnetic tape ring
  • Reading distance ≤0.4 mm
  • Signal period 1000 μm
  • Output circuit sin/cos 1 VSS
  • Robust metal housing

Mechanical Data

Feature Technical data Additional information
Sensor/band reading distance 0.1 … 0.4 mm O, IA, ID reference signal
  0.1 … 0.2 mm reference signal RB, RD
Sensor/ring reading distance 0.1 … 0.4 mm O, IA, ID reference signal
  0.1 … 0.2 mm reference signal RB, RD
Cable sheath PUR, suitable for drag-chain use 6, 8-core ø5-0.4 mm
Cable bending radius 5x cable diameter static
  7.5x cable diameter dynamic
Service life of cable >5 Million cycles Under the following test conditions:
Housing zinc die-cast/aluminum M design
  zinc die-cast ZM design

Electrical Data

Feature Technical data Additional information
Operating voltage 10.5 … 30 V DC reverse polarity protection
  5 V DC ±5 % no reverse polarity protection
Current consumption <25 mA at 24 V DC  
  <50 mA at 5 V DC  
Output signals sin, /sin, cos, /cos, index, /index  
Output voltage 1 Vpp ±10 % at 0 … 70 °C 120 Ω terminal resistance
Output impedance 0 Ω (Rload >75 Ω) short-circuit proof
Signal period 1000 µm  
Offset voltage 2.5 V, ±100 mV sine/cosine mean to GND (10.5 … 30 V DC)
  UB/2 ±100 mV sine/cosine mean to GND (5 V DC)
Phasing 90°±1°, ±3° (20 kHz) sin/cos
  45° sin/cos reference signal is symmetric around the positive intersection point of the sin/cos signals (phase 45°)
Real-time requirement speed-proportional signal output  
Type of connection open cable end  
  plug connector 7/8-pole

System Data

Feature Technical data Additional information
Linearity deviation ±2 µm at TU = 20° C 0.2 mm sensor/strip reading distance
Repeat accuracy 1 µm  
Measuring range  
Circumferential speed ≤20 m/s sin/cos
Travel speed ≤20 m/s sin/cos

 

Ambient Conditions

Feature Technical data Additional information
Ambient temperature -10 … 70 °C  
Storage temperature -30 … 80 °C  
Relative humidity 100% condensation admissible
EMC EN 61000-6-2 interference resistance / immission
  EN 61000-6-4 emitted interference / emission
Protection category IP67 EN 60529
Shock resistance 500 m/s², 11 ms EN 60068-2-27
Vibration resistance 200 m/s², 50 Hz … 2 kHz EN 60068-2-6

 

Technical Drawing