Son derece kompakt artımlı delik milli enkoder, tüm uygulamalar için standart döner enkoderdir. 15 mm’ye kadar tam boy delik mili, son derece sağlam rulman tasarımı ve IP66/IP67’ye kadar yüksek koruma sınıfı sayesinde tüm uygulamalarda güvenle kullanılabilir.

  • Maks. 5000 pulse/devir çözünürlük
  • Maks. Ø15 mm’ye kadar delik milli geçiş
  • Sağlam rulman yapısı
  • -40 … 85 °C çalışma sıcaklığı
  • Yüksek darbe ve titreşim dayanımı

Mechanical Data

Feature Technical data Additional information
Housing die-cast  
Speed ≤12000 min-1 IP65
  ≤6000 min-1 IP65 continuous operation
  ≤6000 min-1 IP66/IP67
  ≤3000 min-1 IP66/IP67 continuous operation
Moment of inertia ~6 x 10-6 kgm2  
Starting torque <0.01 Nm at 20 °C IP65
  <0.05 Nm at 20 °C IP66/IP67
Shaft load rating 100 N radial
  50 N axial
Cable sheath PVC ~Ø 6.7 mm
Cable bending radius 75 mm static
  110 mm dynamic
Weight ~0.4 kg  

Electrical Data

PP output circuit    
Feature Technical data Additional information
Operating voltage 10 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption 50 mA typical ≤100 mA (no load)
Output signal level high ≥UB – 1.0 V short-circuit proof
Output signal level low ≤0.5 V short-circuit proof
Pulse frequency ≤300 kHz  
Load ±20 mA max. adm.
Type of connection 1x M12-plug connector 5-pole, 1x pin
     
OP output circuit    
Feature Technical data Additional information
Operating voltage 10 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption 50 mA typical ≤100 mA (no load)
Output signal level high ≥UB – 1.0 V short-circuit proof
Output signal level low ≤0.5 V short-circuit proof
Pulse frequency ≤300 kHz  
Load ±20 mA max. adm.
Type of connection open cable end  
  1x M23-plug connector 12-pole, 1x pin
     
LD output circuit    
Feature Technical data Additional information
Operating voltage 5 … 30 V DC reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption 40 mA typical ≤90 mA (no load)
Output signal level high ≥2.5 V short-circuit proof, not against UB
Output signal level low ≤0.5 V short-circuit proof, not against UB
Pulse frequency ≤300 kHz  
Load ±20 mA max. adm.
Type of connection open cable end  
  1x M23-plug connector 12-pole, 1x pin

 

System Data

Approval UL UL 61010-1, File No. E503367
     
Characteristics of functional safety  
Feature Technical data Additional information
MTTFd 61.7 Year(s)  

 

Ambient Conditions

Ambient temperature -40 … 85 °C connector
  -30 … 85 °C static laying of cables
  -20 … 85 °C dynamic laying of cables
EMC EN 61326-1 immunity requirement of industry
Safety regulations UL 61010-1 indoor use, outdoor use possible, not intended for use involving direct exposure to UV light.
Protection category IP65, IP66/IP67 EN 60529 (protection type not yet reviewed by UL)
Shock resistance 3000 m/s2, 6 ms EN 60068-2-27
Vibration resistance 300 m/s2, 10 … 2000 Hz EN 60068-2-6

Technical Drawing