Mechanical Data
| Feature | Technical data | Additional information |
| Sensor/band reading distance | ≤1.3 mm | |
| Housing | zinc die-cast |
| Feature | Technical data | Additional information |
| Sensor/band reading distance | ≤1.3 mm | |
| Housing | zinc die-cast |
| Feature | Technical data | Additional information |
| Operating voltage | 4.5 … 30 V DC | reverse polarity protection |
| Power input | 1.5 W | |
| SSI clock speed input | ≤750 kHz | depending on cable length |
| Output circuit | without, LD (RS422) | |
| Interface | SSI, RS485 | |
| CANopen | spec. 2.0A, DS 301, DS 406, ISO 11898 | |
| Baud rate | 0.05 … 1 Mbit/s | CANopen |
| Cycle time | <25 µs | SSI/RS485 |
| <40 µs | CANopen | |
| Type of connection | M12 plug connector (A-coded) | 12-pole, 1x pin |
| M12 plug connector (A-coded) | 5 poles, 1x pin (CANopen) |
| Feature | Technical data | Additional information |
| Resolution | 5, 10 µm | absolute |
| 10 µm | absolute, CANopen factory setting, reconfigurable to 5 µm | |
| 1, 5, 10 µm | incremental | |
| System accuracy | ±(0.02 + 0.03 x L) mm, L in m at TU = 20° C | |
| Repeat accuracy | ≤5 µm, ±1 digit at TU = 20° C | |
| Measuring range | ≤10240 mm | |
| Travel speed | ≤5 m/s | absolute |
| see table | incremental | |
| Feature | Technical data | Additional information |
| Ambient temperature | -30 … 85 °C | |
| Storage temperature | -40 … 85 °C | |
| Relative humidity | 100% | condensation admissible |
| EMC | EN 61000-6-2 | interference resistance / immission |
| EN 61000-6-4 | emitted interference / emission | |
| Protection category | IP67 | EN 60529, with mating connector fitted |
| Shock resistance | 500 m/s², 11 ms | EN 60068-2-27 |
| Vibration resistance | <100 m/s², 5 … 150 Hz | EN 60068-2-6 |